Looking for prices?
Sign in Become a Customer


T18VN6URQ

Banner® T18U Series Opposed Mode Ultrasonic Sensor


T18VN6URQ

T18U Series: Receiver. Range: 300 - 600mm; Input: 12-30V dc. Output: Complementary NPN. Quick-Disconnect Connector.

Sensing Mode (General)
Opposed
Sensing Mode (Detailed)
Receiver
Housing Style
Rectangular w/ M18 Mount
Primary Housing Material
Polybutylene Terephthalate (PBT)
Input/Output
Discrete
Indicator Display Type
LEDs
Max Sensing Distance
600 mm
Sensing Beam
Ultrasonic
Power Supply
12 to 30 VDC
Delay at Power-up
100 ms
Connection
Integral QD
QD Type/Cable Length
M12 (Euro) requires mating cordset
Number of Pins
4 Pin
Vibration
MIL-STD-202F req. Method 201A (vibration: 10 to 60 Hz max., double amplitude 0.06 in, max acc. 10G).
Mechanical Shock
IEC 60947-5-2 Requirements: 30G 11 ms Duration, Half Sine Wave
Mechanical Shock (Additional Comments)
MIL-STD-202G, Meth. 213B, Conditions H&I (Shock: 75G with Unit Operation: 100G for Non-Operation)
Output Saturation Voltage NPN Outputs
< 1.5 V at 10 mA; < 2.0 V at 150 mA
Output Saturation Voltage PNP Outputs
< 1.5 V at 10 mA; < 2.0 V at 150 mA
Max Discrete (Switched) Output
100 mA
Discrete (Switched) Outputs
NPN Complementary
Output Protection
Protected against overload and short circuit conditions. No false pulse upon receiver power-up
IP Rating
IP67
NEMA Rating
NEMA 6P
Max Operating Temperature
70 deg C (158 deg F)
Min Operating Temperature
-40 deg C (-40 deg F)
Minimum Response Time
1 ms
Rep Rate
Normal Resolution Mode: 8 ms; High Resolution Mode: 5 ms
Barrel Diameter
18 mm
Ultrasonic Frequency
230 kHz
Max Off-State Leakage Current
< 1 A at 30 VDC
Power/Current Consumption (Exclusive of Load)
35 mA
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Feature: Clear Object Detection
Yes
Feature: Timing (Hold/Delay)
No
Feature: Chemical Resistant
No
Application: Ultrasonic
Yes
IO Link
No
RS-232
No
RS-422
No
RS-485
No
SSI
No
Wireless
No Wireless Capability
1-Wire Serial Interface
No
Profibus
No
Add to Cart