We’ve encountered an issue with your company account, so you will be unable to complete checkout. Please contact ar@ebhorsman.com for resolution

AJT100

Stocked Stock status at one or more E.B. Horsman location(s). Login or register for specific inventory by location.
Mersen 100A Low Voltage Time Delay Power Fuse, Class J, Indicating, 600 VAC/500 VDC, 200/100 kA
$61.99
/ each
minimum order: 1 pieces

Available to Ship Same Day if Stocked at Local Branch and Order Placed before 1:00 PM

Manufacturer: Mersen
Brand: Mersen
PN: #AJT100

Product Information

Mersen Amp-Trap 2000 SmartSpot Power Fuse, Current Limiting Low Voltage North American Time Delay, Series: AJT, Indicating, Rejection, 100 A, 600 VAC/500 VDC, 200 kA Interrupt, Class: J, Blade Terminal, Clip Mounting, Cylindrical Body, Dual Element, Fiberglass, 1-1/16 in Dia x 4-5/8 in L Body
UPC 78200196248 Product Type Class J Fuses, UL Class Fuses
Amperage Rating 100 A Indicating/Non-Indicating Indicating
Speed/Characteristic Time Delay Voltage Rating 600 VAC/500 VDC
Element Dual Frequency Rating 50/60 Hz
Fuse Body Type Cylindrical Fuse Class Class J
Fuse Style North American Style Fuse Type Current Limiting Low Voltage
Interrupt Rating 200 kA AC/100 kA DC Material Fiberglass
Mounting Type Clip Overall Diameter 1-1/16 in (27 mm)
Overall Length 4-5/8 in (11.7 cm) Rejection/Non-Rejection Rejection
Series AJT Terminal Type Blade
UPC 78200196248
Product Type Class J Fuses, UL Class Fuses
Amperage Rating 100 A
Indicating/Non-Indicating Indicating
Speed/Characteristic Time Delay
Voltage Rating 600 VAC/500 VDC
Element Dual
Frequency Rating 50/60 Hz
Fuse Body Type Cylindrical
Fuse Class Class J
Fuse Style North American Style
Fuse Type Current Limiting Low Voltage
Interrupt Rating 200 kA AC/100 kA DC
Material Fiberglass
Mounting Type Clip
Overall Diameter 1-1/16 in (27 mm)
Overall Length 4-5/8 in (11.7 cm)
Rejection/Non-Rejection Rejection
Series AJT
Terminal Type Blade
Amp-Trap 2000 SmartSpot AJT fuses now provide a visual open fuse indicator. With advanced material technology the AJT fuse provides IEC type-2 no damage protection to main, feeder and branch circuits, for all types of loads - yet, they require only half the mounting space needed for 600 VAC Class RK fuses. AJT's time delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current limiting ability.
Data Sheet (246.44 kB)
Need help?
Report product info issue

REPORT PRODUCT INFORMATION ISSUE

We recognize how important product data accuracy is to our customers. If you have identified an issue with any of our products, please get in touch! A member of our customer service team will review the issue and work to resolve it as quickly as possible. Thank you for contributing to the improvement of our online store!

NEED HELP

We’re here to help! Simply fill out the form below to get in touch with a member of our customer support team.