TR45R
Available for Backorder
Stock status at one or more E.B. Horsman location(s). Login or register for specific inventory by location.
Mersen Tri-Onic 45A Low Voltage Time Delay Fuse, 250 VAC/VDC, 200/20 kA, Class RK5
$10.99
/ each
minimum order: 1 pieces
Available to Ship Same Day if Stocked at Local Branch and Order Placed before 1:00 PM
Manufacturer:
Mersen
Brand:
Mersen
PN:
#TR45R

Product Information
Mersen Tri-Onic Time Delay Fuse, Current Limiting Low Voltage, Series: TR-R, Non-Indicating, Rejection, 45 A, 250 VAC/VDC, 200/20 kA Interrupt, Class: RK5, Ferrule Terminal, Clip Mounting, Cylindrical Body, Dual Element, Polyester, 13/16 in Dia x 3 in L Body
UPC | 78200174792 | Product Type | Class RK5 Fuses, UL Class Fuses |
Amperage Rating | 45 A | Fuse Class | Class RK5 |
Indicating/Non-Indicating | Non-Indicating | Speed/Characteristic | Time Delay |
Voltage Rating | 250 VAC/VDC | CSA Rating | CSA C22.2 No. 248.12 |
Element | Dual | Fuse Body Type | Cylindrical |
Fuse Type | Current Limiting Low Voltage | Interrupt Rating | 200/20 kA |
Material | Polyester | Mounting Type | Clip |
Overall Diameter | 13/16 in (20.6 mm) | Overall Length | 3 in (76.2 mm) |
Rejection/Non-Rejection | Rejection | Series | TR-R |
Terminal Type | Ferrule | UL Rating | UL Listed 248-12 File E2137 |
UPC | 78200174792 | Product Type | Class RK5 Fuses, UL Class Fuses |
Amperage Rating | 45 A | Fuse Class | Class RK5 |
Indicating/Non-Indicating | Non-Indicating | Speed/Characteristic | Time Delay |
Voltage Rating | 250 VAC/VDC | CSA Rating | CSA C22.2 No. 248.12 |
Element | Dual | Fuse Body Type | Cylindrical |
Fuse Type | Current Limiting Low Voltage | Interrupt Rating | 200/20 kA |
Material | Polyester | Mounting Type | Clip |
Overall Diameter | 13/16 in (20.6 mm) | Overall Length | 3 in (76.2 mm) |
Rejection/Non-Rejection | Rejection | Series | TR-R |
Terminal Type | Ferrule | UL Rating | UL Listed 248-12 File E2137 |
Tri-Onic TR-R current limiting time delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch circuits. The time delay characteristics of the TR-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.
REPORT PRODUCT INFORMATION ISSUE
We recognize how important product data accuracy is to our customers. If you have identified an issue with any of our products, please get in touch! A member of our customer service team will review the issue and work to resolve it as quickly as possible. Thank you for contributing to the improvement of our online store!
NEED HELP
We’re here to help! Simply fill out the form below to get in touch with a member of our customer support team.