Mersen Tri-Onic 75A Low Voltage Time Delay Fuse, 250 VAC/VDC, 200/20 kA, Class RK5
$29.99
/ each
minimum order: 1 pieces

Available to Ship Same Day if Stocked at Local Branch and Order Placed before 1:00 PM

Manufacturer: Mersen
Brand: Mersen
PN: #TR75R

Product Information

Mersen Tri-Onic Time Delay Fuse, Current Limiting Low Voltage, Series: TR-R, Non-Indicating, Rejection, 75 A, 250 VAC/VDC, 200/20 kA Interrupt, Class: RK5, Blade Terminal, Clip Mounting, Cylindrical Body, Dual Element, Polyester, 1-1/16 in Dia x 5-7/8 in L Body
UPC 78200174798 Product Type Class RK5 Fuses, UL Class Fuses
Amperage Rating 75 A Fuse Class Class RK5
Indicating/Non-Indicating Non-Indicating Speed/Characteristic Time Delay
Voltage Rating 250 VAC/VDC CSA Rating CSA C22.2 No. 248.12
Element Dual Fuse Body Type Cylindrical
Fuse Type Current Limiting Low Voltage Interrupt Rating 200/20 kA
Material Polyester Mounting Type Clip
Overall Diameter 1-1/16 in (27 mm) Overall Length 5-7/8 in (14.9 cm)
Rejection/Non-Rejection Rejection Series TR-R
Terminal Type Blade UL Rating UL Listed 248-12 File E2137
UPC 78200174798
Product Type Class RK5 Fuses, UL Class Fuses
Amperage Rating 75 A
Fuse Class Class RK5
Indicating/Non-Indicating Non-Indicating
Speed/Characteristic Time Delay
Voltage Rating 250 VAC/VDC
CSA Rating CSA C22.2 No. 248.12
Element Dual
Fuse Body Type Cylindrical
Fuse Type Current Limiting Low Voltage
Interrupt Rating 200/20 kA
Material Polyester
Mounting Type Clip
Overall Diameter 1-1/16 in (27 mm)
Overall Length 5-7/8 in (14.9 cm)
Rejection/Non-Rejection Rejection
Series TR-R
Terminal Type Blade
UL Rating UL Listed 248-12 File E2137
Tri-Onic TR-R current limiting time delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch circuits. The time delay characteristics of the TR-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.
Data Sheet (279.41 kB)
Need help?
Report product info issue

REPORT PRODUCT INFORMATION ISSUE

We recognize how important product data accuracy is to our customers. If you have identified an issue with any of our products, please get in touch! A member of our customer service team will review the issue and work to resolve it as quickly as possible. Thank you for contributing to the improvement of our online store!

NEED HELP

We’re here to help! Simply fill out the form below to get in touch with a member of our customer support team.